MW 1000 Calculator
MW 1000 Calculator
[mw_1000_calculator_awg_size_drop_down post_type="mw-1000-calculator"]
Dimensions for Bare and Film Insulated Round Magnet Wire (Inch)
Bare Wire
Minimum
0.0024
Nominal
0.0025
Maximum
0.0026
Single Build
Minimum Increase
0.0002
Maximum Overall
0.003
Heavy Build
Minimum Increase
0.0005
Maximum Overall
0.0033
Triple Build
Minimum Increase
0.0007
Maximum Overall
0.0036
Quad Build
Minimum Increase
0.0009
Maximum Overall
0.0039
Minimum Dielectric Breakdown (V/rms)*
Single Build
Film Insulated Wire without Polyamide Topcoat
375
Film Insulated Wire with Polyamide Topcoat
350
Heavy Build
Film Insulated Wire without Polyamide Topcoat
700
Film Insulated Wire with Polyamide Topcoat
650
Triple Build
Film Insulated Wire without Polyamide Topcoat
990
Film Insulated Wire with Polyamide Topcoat
890
Quad Build
Film Insulated Wire without Polyamide Topcoat
1270
Film Insulated Wire with Polyamide Topcoat
1145
MW 16-C
* Test procedure used:
- 38-56 AWG - Cylinder Method
- 8-37 AWG - Twisted Pair Method
- Larger than 8 AWG - Foil Method