MW 1000 Calculator
MW 1000 Calculator
[mw_1000_calculator_awg_size_drop_down post_type="mw-1000-calculator"]
Dimensions for Bare and Film Insulated Round Magnet Wire (Inch)
Bare Wire
Minimum
0.0448
Nominal
0.0453
Maximum
0.0458
Single Build
Minimum Increase
0.0014
Maximum Overall
0.0475
Heavy Build
Minimum Increase
0.0028
Maximum Overall
0.0488
Triple Build
Minimum Increase
0.0041
Maximum Overall
0.0502
Quad Build
Minimum Increase
0.0055
Maximum Overall
0.0516
Minimum Dielectric Breakdown (V/rms)*
Single Build
Film Insulated Wire without Polyamide Topcoat
3250
Film Insulated Wire with Polyamide Topcoat
2930
Heavy Build
Film Insulated Wire without Polyamide Topcoat
5850
Film Insulated Wire with Polyamide Topcoat
5260
Triple Build
Film Insulated Wire without Polyamide Topcoat
7810
Film Insulated Wire with Polyamide Topcoat
7030
Quad Build
Film Insulated Wire without Polyamide Topcoat
10170
Film Insulated Wire with Polyamide Topcoat
9150
MW 16-C
8290
* Test procedure used:
- 38-56 AWG - Cylinder Method
- 8-37 AWG - Twisted Pair Method
- Larger than 8 AWG - Foil Method